What is PUE?

11/1/2024

 
Picture
In 2007, The Green Grid (TGG) that is an affiliate member organization of the Information Technology Industry Council (ITI) proposed Power Usage Effectiveness (PUE), is the ratio of the total facility power consumption divided by the IT equipment power consumption.
Power Usage Effectiveness (PUE) has been the basis indicator for evaluating the energy efficiency of data centers, also helps data centers to improve the efficiency of good energy consumption monitoring.

​
What is PUE?
Picture
According to the International Energy Agency (IEA) report, in 2021, the global energy consumption of data centers reached 220 to 320 billion kWh, accounting for 0.9% to 1.3% of the worldwide power usage. In Taiwan, the total power consumption was 283 billion kWh last year and estimated among 3.7 billion kWh by data centers. Data volumes grow rapidly which are doubling every two years with big data application flourishing. To reduce power consumption and increase spatial capacity are goals of enterprises data centers development in the future. An ideal PUE would be 1.0. However, data centers require cooling systems, lighting, and other equipment that will also consume some power. Therefore, the PUE of data center will always be greater than 1.0. The main power consumption of data center is including IT servers, refrigeration equipment, power supply & distribution system, lighting and other systems. According to statistical reports, the power consumption distribution of data center is roughly as follows:
Picture
How to get lower PUE?
By separating hot and cold aisles, improving power usage of IT gears, using energy-saving uninterruptible power supply (UPS) and lighting facilities, PUE can be effectively reduced with these traditional methods. However, that will be the key factor to reduce PUE with the application with immersion cooling system from traditional air-cooling system.
Picture
Source: OCP summit, March 2018

Market case of global data center PUE approaching 1.0
  • Alibaba Cloud Zhejiang data center got lower PUE to 1.09 by single phase immersion cooling system without fan and A/C facilities.
  • The energy efficiency of each of Google's large-scale data centers (data centers that are already in stable operation) in 2023, and the actual returned PUE value is 1.10, and this data includes all indirect electricity consumption.
  • Facebook have developed an indirect cooling technology, called the StatePoint Liquid Cooling (SPLC) system which have completed in 2022 exhibit a Power Usage Effectiveness (PUE) of 1.09 and Water Usage Effectiveness (WUE) of 0.20. 

​What KAORI can do?
KAORI EMBU team developed In-Row 800kW L/L (Liquid to Liquid) CDU (Coolant Distribution Unit) systems, In-Rack 80kW Direct-to-Chip (D2C) Cold Plate CDU systems, as well as 2U3kW/4U7kW/25U90kW immersion cooling systems to offer a variety of different solutions to help data centers for lower PUE. KAORI offers different solutions to help data center to reduce PUE by above efficient liquid cooling solutions.
Back to NEWS

Comments are closed.

    Article

    The Rising Trend in Data Centers: Liquid Cooling Technology
    The Rising Trend in Data Centers: Liquid Cooling Technology
    Picture
    KAORI Thermal Technology @ Computex 2025
    Picture
    Breakthrough in Liquid Cooling High Performance In-Row CDU
    Picture
    Future Engery - Saving Trends In-Rack D2C liquid Cooling Systems
    Picture
    Immersion Cooling Fliud : Hydrocarbons vs. Fluorocarbons
    Picture
    What is PUE? How to Enhance Energy Efficiency in Liquid Cooling Systems?
    Picture
    Kaori’s Thermal Solution Technologies High-Performance Capabilities and Competitiveness
Picture


​​Copyright @2025 Kaori Thermal Technology Co.,Ltd.

  • Solutions
  • News
  • Company
  • Contact Us